B-VENT IMPROVEMENTS
We are improving the lock on our B-Vent raincaps to ensure that they stay assembled with the B-Vent when subject to the high winds experienced in some areas. The improvements include the following:
The Raincap collars will be standardized with four (4)
deeper dimples to match up with the four (4) notches in the male end of the
B-Vent. To install the raincap, align the four (4) dimples on the raincap
collar with the four (4) notches on the male end of the B-Vent. Push on
raincap tight to the B-Vent and rotate the raincap 1/8 turn in either
direction. The deeper dimples lock under the curled male end of the B-Vent
as before and provide a more secure joint.
Note: The Raincap can also be installed the old way, without aligning
the dimples, just push the Raincap on until the dimples snap under the
curled male end of the B-Vent.